Last edited by Mikar
Monday, October 12, 2020 | History

2 edition of digital correlator for flow measurement applications. found in the catalog.

digital correlator for flow measurement applications.

C N. McCurdy

digital correlator for flow measurement applications.

by C N. McCurdy

  • 91 Want to read
  • 12 Currently reading

Published in Bradford .
Written in English


Edition Notes

M.Sc. dissertation. Typescript.

SeriesDissertations
The Physical Object
Pagination1 vol
ID Numbers
Open LibraryOL13693430M

  Here is sketch diagram shows the arrangement of a hot wire anemometer used for the measurement fitted with a wheatstone bridge. LASER DOPPLER ANEMOMETER AND ITS APPLICATIONS []. It is a very advanced type of anemometer offers the advantage that they do not disturb the flow during the measurement is a optical type of flow meter and it can also . Ultrasonic range gated flow measurement using a microprocessor controlled digital correlator. Author: Pogaridis, Dimitrios. ISNI: Awarding Body: University of Salford Current Institution: University of Salford Date of Award:

  ``Anyone involved in the selection or operation of slowmeters should have access to this book''N--Applied Mechanics Review. Through two previous editions, thousands of international engineers have turned to this handbook for reliable and complete information on the selection, design, specification, and installation of flowmeters to measure liquid, gas, and steam flows within all engineering Reviews: MV 82 Vortex Flow Meter- The PanaFlow MV82 insertion mass flow meter is a multivariable vortex flow meter for measuring volumetric flow, temperature, pressure, density and mass flow. It offers an advanced design and digital signal processing to isolate vibration. This meter is accurate, reliable and cost effective for measuring any process flow.

a digitrac digital computer was successfully used to provide an automatic flight and weapons control system. Figure The proposed use of computer in measurement and control Late s itself saw the application of digital computers in industrial measurement & . A practical guide to cutting-edge techniques for flow measurement and control Unlike any other book on the subject, this volume employs practical applications to illustrate flow measurement techniques in industrial processes. Drawing on their work at the Oak Ridge National Laboratory, five leading researchers present applications that test the limits of commercial flow instrumentation-in harsh.


Share this book
You might also like
poetry of Hartley Coleridge

poetry of Hartley Coleridge

Wars embers, and other verses.

Wars embers, and other verses.

LIT WITCHES BG NI-PK

LIT WITCHES BG NI-PK

Garden flora

Garden flora

We are shopping

We are shopping

Velazquez, 1599-1660

Velazquez, 1599-1660

Channel tunnel survey of car users

Channel tunnel survey of car users

1990 census of population and housing.

1990 census of population and housing.

Elements of ecology.

Elements of ecology.

The Knowhow Book of Batteries and Magnets

The Knowhow Book of Batteries and Magnets

The honey bee

The honey bee

Demographic analysis

Demographic analysis

John M. Hartman.

John M. Hartman.

Digital correlator for flow measurement applications by C N. McCurdy Download PDF EPUB FB2

The rapid adoption of DCS for clinical flow monitoring was aided by the availability of user-friendly and convenient hardware correlators (e.g.,Bridgewater, New Jersey; ALB, Hessen, Germany), but this convenience also limited measurement ionally, correlators employ embedded programming and a multi-tau algorithm [45–47] to compute the autocorrelation Cited by:   Digital image correlation and tracking is an optical method that employs tracking and image registration techniques for accurate 2D and 3D measurements of changes in images.

This method is often used to measure full-field displacement and strains, and it is widely applied in many areas of science and engineering, with new applications being found all the time. Design of cross-correlation techniques in flow measurement The correlator needed for industrial on-line instrumentation is quite different from the general sophisticated signal analyzer.

A special digital correlator, which periodically calculates the cross correlation, locates the peak position and outputs an equivalent velocity signal, is Cited by: 2.

Abstract. Spectron Development Laboratories, Inc., has implemented a 5 ns interval correlator for photon detection, ultrasonic acoustics, and other applications where existing digital correlators have been too slow or had too few : A.

Smart, W. Mayo. 1. Introduction. Cross correlation techniques are well-known and are becoming widely used in both laboratory and industry for pipeline flow velocity measurement 1, 2.A solid or liquid flow in a pipeline produces random disturbance signals which can be detected by various types of transducer, e.g.

capacitance and electrodynamic transducers 3, 4, find the time delay of flow patterns, an up Cited by: This book presents the fundamentals of Digital Signal Processing using examples from common science and engineering problems.

While the author believes that the concepts and data contained in this book are accurate and correct, they should not be used in any application without proper verification by the person making the application. From the delay time and the distance between the two sensors the correlator calculates the velo­ city of the moved system.

moved system ups t ream sensor cross-correlator v(t) signal proportional to velocity Fig. 1 Basic structure of a cross-correlation velocity measurement The main idea of a cross-correlation velo­city-or flow-measurement. 2. Diffuse Correlation Spectroscopy Background.

As noted above, DCS is an emerging optical modality to monitor CBF. In recent years, excellent reviews about the theory, instrumentation, validation, and clinical applications of DCS have been published, and the interested reader will enjoy these papers.

1 – 5 DCS detects blood flow by quantifying temporal fluctuations of light fields. illustration of a correlation received signal, x[n], and the cross-correlation signal, y[n], are fixed on the waveform we are looking for, t[n], commonly called the target signal, is contained within the correlation machine.

Each sample in y[n] is calculated by moving the correlation machine left or right until it points to the sample being worked on. International Journal of Computer Applications ( – ) Volume 66– No, March 21 Fig block diagram of the ultrasonic cross-correlation flow measurement system The demodulated signals were further filtered with   This gives a very high spatial resolution and covers a wide range of flow velocities besides its simplicity, but the data processing is very costly.

The MALVERN correlator is widely used to compute the correlation function for such measurement. It is a digital photon correlator. In robotics applications, however, the accuracy of a measurement is influenced substantially by temperature fluctuations and air flow.

This effect must be compensated by measuring the ambient temperature and air flow velocity, if precise measurements (1 mm) are required. This would result in a need to increase the complexity and hardware costs.

Cross correlator is the core device of the cross-correlation flow measurement system. This paper describes the theory of the cross-correlation flow measurement system and realizes the digital.

To determine flow, simply read thegraduated markings at the center of the float. Variable area flowmeters can be used in laboratory and industrial applications, and when compared with other types of flow instrumentation, are the most economical for indicating flow rate measurement when taking into account practicality and accuracy.

aeroengine development to measure flow and turbu- important area of application for the correlator, and a. using various analog and digital correlators, reaching ns time resolution. Digital comparator correlator system (DCCS).

ISPRS J. Photogramm. Re mote Sensing, This paper describes the Digital Comparator Correlator System (DCCS), developed by Helava Associates, Incorporated (HAI) for automatic selection and measurement of tie.

Experiment (4): Flow measurement Introduction: The flow measuring apparatus is used to familiarize the students with typical methods of flow measurement of an incompressible fluid and, at the same time demonstrate applications of the Bernoulli's equation.

The flow is determined using a sudden enlargement, venturi meter, orifice plate, elbow and. McMaster-Carr is the complete source for your plant with overproducts. 98% of products ordered ship from stock and deliver same or next day. Cross correlator design for flow measurement: the design of digital and hybrid cross correlators for time delay measurement, and an analysis of some sources of error, with particular application to flow measurement Author: Hayes, Alan Michael.

For example, observations of the CMB spatial intensity variations require measurement of the XX and YY products only.

Zoom In Zoom Out Reset image size Figure 1. Block diagram of the AMiBA correlator. Signal flow for one baseline (1X2X) is presented. Following the correlator module, the signal flow for a particular lag (lag 4) is depicted.

A catalog record for this book is available from the British Library. Library of Congress Cataloging in Publication Data Baker, R. C. Flow measurement handbook:industrial designs, operating principles, performance, and applications / Roger C.

Baker. p. cm. Includes bibliographical references. ISBN 0 .measuring the flowrate and quantities of flowing fluids are described and compared. Numerous practical details provide the user with valuable information about flow metering in industrial applications.

Industrial flow measurement Industrial flow measurement Basics and practice DBU02 Rev. 08 .DIGITEN Water Flow Control Meter LCD Display Controller+G1/2" Water Hall Sensor Flow Meter Flowmeter Counter L/min+G1/2" Solenoid Valve Normally Closed N/C+DC 12V Power Adapter by DIGITEN $ $ 99 - $ $